All public logs

From PHYSpedia
Jump to: navigation, search

Combined display of all available logs of PHYSpedia. You can narrow down the view by selecting a log type, the username (case-sensitive), or the affected page (also case-sensitive).

Logs      

Show tag log

  • 12:59, 2 December 2016 Lbender (talk | contribs) uploaded File:TABLE.PNG (Table of the cooling constants for all of the configurations in the experiment)
  • 12:39, 2 December 2016 Lbender (talk | contribs) uploaded File:AY.png (The average data for the Yeti cup)
  • 12:39, 2 December 2016 Lbender (talk | contribs) uploaded File:ASTY.png (The average data for the styrofoam cup)
  • 12:38, 2 December 2016 Lbender (talk | contribs) uploaded File:AC.png (The average data for the coozie)
  • 12:38, 2 December 2016 Lbender (talk | contribs) uploaded File:KOA.png (The average data for the MyBevi cup)
  • 15:19, 1 December 2016 Lbender (talk | contribs) uploaded File:Thermal Project Averages.xlsx (The data for the average of each trial for the Newton's Law of cooling experiment)
  • 15:18, 1 December 2016 Lbender (talk | contribs) uploaded File:Thermal Project Data.xlsx (The data for the Newton's Law of Cooling Experiment)
  • 23:32, 30 November 2016 Lbender (talk | contribs) uploaded File:S3.png (The third trial using a styrofoam cup. This trial yielded a value of 11.5 ± 0.3 (1/min) for the cooling constant.)
  • 23:31, 30 November 2016 Lbender (talk | contribs) uploaded File:S2.png (The second trial using a styrofoam cup. This trial yielded a value of 12.2 ± 0.3 (1/min) for the cooling constant.)
  • 23:31, 30 November 2016 Lbender (talk | contribs) uploaded File:S1.png (The first trial using a styrofoam cup. This trial yielded a value of 12.8 ± 0.2 (1/min) for the cooling constant.)
  • 23:29, 30 November 2016 Lbender (talk | contribs) uploaded File:KO3.png (The third trial using the MyBevi brand cup. This trial yielded a value of 5.34 ± 0.02 (1/min) for the cooling constant.)
  • 23:29, 30 November 2016 Lbender (talk | contribs) uploaded File:KO2.png (The second trial using the MyBevi brand cup. This trial yielded a value of 5.16 ± 0.02 (1/min) for the cooling constant.)
  • 23:28, 30 November 2016 Lbender (talk | contribs) uploaded File:KO1.png (The first trial using the MyBevi brand cup. This trial yielded a value of 5.51 ± 0.03 (1/min) for the cooling constant.)
  • 23:27, 30 November 2016 Lbender (talk | contribs) uploaded File:C3.png (The third trial using the Yeti brand coozie. This trial yielded a value of 5.97 ± 0.09 (1/min) for the cooling constant.)
  • 23:26, 30 November 2016 Lbender (talk | contribs) uploaded File:C2.png (The second trial using the Yeti brand coozie. This trial yielded a value of 5.20 ± 0.07 (1/min) for the cooling constant.)
  • 23:26, 30 November 2016 Lbender (talk | contribs) uploaded File:C1.png (The first trial using the Yeti brand coozie. This trial yielded a value of 4.89 ± 0.02 (1/min) for the cooling constant.)
  • 23:24, 30 November 2016 Lbender (talk | contribs) uploaded File:Y3.png (The third trial using the Yeti brand cup. This trial yielded a value of 4.61 ± 0.03 (1/min) for the cooling constant.)
  • 23:23, 30 November 2016 Lbender (talk | contribs) uploaded File:Y2.png (The first trial using the Yeti brand cup. This trial yielded a value of 4.5 ± 0.1 (1/min) for the cooling constant.)
  • 23:22, 30 November 2016 Lbender (talk | contribs) uploaded File:Y1.png (The first trial using the Yeti brand cup. This trial yielded a value of 4.3 ± 0.2 (1/min) for the cooling constant.)